A0

Energy class A0

According to the design-stage energy assessment, the 3 Háje Kľušov buildings are rated energy class A0 – a nearly zero-energy building.

IndicatorDesigned buildingkWh/(m²·a)RequirementkWh/(m²·a)Rating
Specific heat demand for heating (Qh,nd)17,21≤ 26,70complies
Energy performance of the building (QEP)13,88≤ 28,85complies
Energy demand for heating8,49≤ 28class A
Energy demand for domestic hot water7,11≤ 12class A
Total energy demand16,79≤ 46class A
Global indicator – primary energy37,09≤ 39class A0

Values in kWh per m² of floor area per year; the requirement is the normalised (maximum) value.

Class A0 requires both conditions at the same time

  1. 1The global indicator – primary energy – is at or below the upper limit of energy class A0: met.
  2. 2The building uses a renewable energy source in at least one place of consumption: met.
A0
Nearly zero-energy building

The calculated primary-energy indicator of the designed building falls into energy class A0 and meets the minimum energy-performance requirement under Slovak Act No. 555/2005 Coll.

How it is achieved

  • External walls of 300 mm Termalica masonry with 150 mm thermal insulation (U = 0.14 W/m²K)
  • Roof insulated with 300 mm EPS (U = 0.11 W/m²K)
  • Ground floor slab with 140 mm insulation, ceilings above the exterior insulated on both sides
  • Aluminium windows with insulating triple glazing (Ug = 0.6 W/m²K)
  • Window ventilation complemented by local heat-recovery ventilation units in the living rooms

Heating and utilities

  • Electric DEVI heating with smart control.
  • The buildings will be connected to the public sewer system being built in Kľušov.

Source: design-stage energy assessment of the building for the building-permit documentation, Ing. Pavol Fedorčák, PhD., April 2026, prepared under Decree No. 324/2016 Coll. The energy certificate is issued at final building approval.

3 Háje Kľušov
3 Háje Kľušov
3 Háje Kľušov
3 Háje Kľušov
3 Háje Kľušov